Chapter 7 Fastening Instructions
PAGE 7-34
AFC1500/AFC3000 Fastening Parameter (Rate) Correspondence Table
AFC1500
Fastening Parameter
Data No.
AFC3000
Fastening Parameter
Data No.
Function
17 Threshold Torque 112 1
st
Rate Start Torque
Set the torque value of 1
st
torque rate
measurement start point
15 1
st
Torque
(1
st
Rate End Torque)
113 1
st
Rate End Torque
Set the torque value of 1
st
torque rate
measurement end point
1E 2
nd
Rate
Start Torque
114 2
nd
Rate Start Torque
Set the torque value of 2
nd
torque rate
measurement start point
18 CROS Torque
(2
nd
Rate End Torque
3
rd
Rate Start Torque)
115 2
nd
Rate End Torque
Set the torque value of 2
nd
torque rate
measurement end point
116 3
rd
Rate Start Torque
Set the torque value of 3
rd
torque rate
measurement start point
13 Standard Torque
(3
rd
Rate End Torque)
117 3
rd
Rate End Torque
Set the torque value of 3
rd
torque rate
measurement end point
23 1
st
Angle
(1
st
Rate End Angle)
Set the angle value of 1
st
torque rate
measurement end point
26 2
nd
Rate Start Angle
Set the angle value of 2
nd
torque rate
measurement start point
24 CROS Angle
(2
nd
Rate End Angle
3
rd
Rate Start Angle)
Set the angle value of 2
nd
torque
rate measurement end point
Set the angle value of 3
rd
torque rate
measurement start point
27 3
rd
Rate Start Angle
22 Standard Angle
(3
rd
Rate End Angle)
Set the angle value of 3
rd
torque
rate
measurement end point

Table of Contents