How to Use a Fluke Networks Quick Clean
Cleaner
WCaution
To prevent damage to the device and to connectors
and to keep contamination off of endfaces, read all
instructions and obey all safety precautions given in
the instructions for the device you use to clean
connectors.
To clean the connectors on test reference cords, use
wipes and solvent. The Quick Clean cleaner cleans
the fiber core, but can leave contamination around
the core. The contamination can move to the core
when you make connections. See “To Clean
Connector Ends” on page 96.
Note
You can use the Quick Clean cleaners to clean APC
endfaces.
1 Use the video probe to inspect the connector. If it is dirty,
continue to step 2.
2 To clean a bulkhead connector, remove the cap. To clean the
connector on a fiber cable, remove only the tip of the cap.
3 If necessary for a bulkhead connector, extend the tip of the
device.
4 Push the device straight into the connector until you hear a
loud click. See Figure 35 or Figure 36. Then remove the device.
5 Use the video probe to inspect the connector. If necessary,
clean and inspect the connector again.
If the mechanical device does not clean the connector
sufficiently, use a swab and solvent to clean the connector.