Versiv Series Cabling Certification Product Family
Users Manual
128
Defects Tab
The DEFECTS tab shows the number and size of the Scratches and
Defects such as a particle of dirt, a chip, or a pit located in each
zone. See Figure 51.
Figure 51. Defects Tab (Single Fiber shown)
Zone A shows defects located in the core.
The measurement rings show after you tap ANALYZE. The sizes
of the rings are specified by the limit. To specify different sizes,
make a custom endface limit.
Zone B shows defects located in the cladding.
Zone D shows defects located in the contact zone.
There are no scratches in the zones greater than the allowable
size or number.
This defect is green because the limit allows for a greater
number of defects of this size or smaller in this zone.
This defect is red because there are a greater number of defects
of this size than the limit allows in this zone.
www.GlobalTestSupply.com