EasyManua.ls Logo

Fluke Versiv Series - Monitor Optical Power

Fluke Versiv Series
377 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Monitor Optical Power
317
GPU138.EPS
Figure 122. Connections to Monitor Power and Loss
To monitor loss
On the POWER METER / LIGHT SOURCE screen, tap REF to use the
present power level as a reference. The meters show the difference
between the reference power levels and the measured power levels.
To save the power and loss measurements
1 On the POWER METER / LIGHT SOURCE screen, tap SAVE.
2 On the SAVE RESULT screen, select End 1 or End 2, make sure
the Cable ID and End name are correct, then tap SAVE. Saved
power meter results show these icons for End 1 and
End 2:
The tester saves the present, minimum, maximum, and reference
power and loss measurements for both wavelengths in one record.
Power at the
end of a link
Power from an
optical source
Optical network
interface card or
optical power source
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com