Fluke Versiv Series - PASS*;FAIL* Results

Fluke Versiv Series
377 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Certify Twisted Pair Cabling
Twisted Pair Autotest Results
61
PASS*/FAIL* Results
A result shows an asterisk when measurements are in the tester’s
accuracy uncertainty range (Figure 23) and the asterisk is required
by the selected test limit. These results are marginal.
A PASS* shows that the cable’s performance is
satisfactory. If a cable must get a PASS result to agree with
your requirements for quality, identify and correct the
problems with the cable and do the Autotest again.
Usually, a FAIL* is not a satisfactory result. The tester
shows a FAIL for the overall result. Identify and correct the
problems with the cable and do the Autotest again.
GPU87.EPS
Figure 23. PASS* and FAIL* Results
Tester’s accuracy
uncertainty
range
PASS
PASS*
FAIL
Limit
FAIL*
PASS*
www.GlobalTestSupply.com