EasyManua.ls Logo

Fluke Versiv Series - Autotest Results for Smart Remote Mode

Fluke Versiv Series
377 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Versiv Series Cabling Certification Product Family
Users Manual
164
If you are not sure you are connected to the correct
fibers, connect the main tester’s INPUT fiber to different
connections until the test continues or the INPUT fiber
on the display is green. Then if necessary, connect the
remote’s INPUT fiber to different connections until the
test continues.
3-5 If Bi-directional is On: Halfway through the test, the tester
tells you to switch the input and output fibers. See “Bi-
directional Tests” on page 185.
3-6 Save the result:
If Auto Save is on, the tester uses the next two IDs to save
the results for the two fibers.
If Auto Save is off, tap SAVE if the test passed or FIX
LATER if the test failed. The SAVE RESULT screen shows
the next two IDs available. You can change the IDs if
necessary.
Autotest Results for Smart Remote Mode
Unsaved results show the results for both fibers. See Figure 62.
The overall result for the Autotest.
The fiber IDs and the loss and length measurements for the
fibers:
The result exceeds the limit.
The result is within the limit.
The selected test limit does not have a limit for the test.
To see the results, limits, and margins for a fiber, tap the
window.
The settings the tester used for the test.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com