EasyManua.ls Logo

Fluke Versiv Series - Use the HDR OTDR; Overview of Features

Fluke Versiv Series
377 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
245
Chapter 8: Use the HDR OTDR
WWarningX*
Before you use the tester, read the safety
information that starts on page 6.
Overview of Features
The OptiFiber
®
Pro HDR (High Dynamic Range) Optical Time
Domain Reflectometer (OTDR) module attaches to a Versiv and
Versiv
2 main unit to make a rugged, hand-held tester that lets
you locate, identify, and measure reflective and loss events on
single-mode fibers in outside plant (OSP) and premises
installations. The HDR OTDR test results includes the location and
performance of unpowered (passive) splitters used in PON
(passive optical network) installations. A typical maximum test
range is 260 km for a link with no splitters. The modules includes
these features:
Automatic analysis of OTDR traces and events helps you
identify and locate faults on single-mode fiber.
Shows OTDR results as an intuitive map of events, a table of
events, and an OTDR trace. PON OTDR test results include the
locations and split ratios of optical splitters.
Automatic bi-directional averaging gives you more accurate
loss measurements than measurements made in one
direction.
Gives a PASS or FAIL result based on a test limit that you
specify.
Document PON test limit is available if PASS/FAIL results are
not necessary.
Event editing function lets you edit loss events. See Chapter 9.