Chapter 5: FiberInspector™ Pro Tests
Charge the FI-3000 Battery
103
Charge the FI-3000 Battery
Before you use the Probe for the first time, charge the battery for
2 hours with the tester turned off. See Figure 39. The battery
charges in 5 hours. A fully-charged battery operates for
10 hours of typical use.
Note
You do not need to fully discharge the battery before
you recharge it.
The battery will not charge if its temperature is
outside the range of 32 °F to 113 °F (0 °C to 45 °C) or if
it has a fault and must be replaced.
With the Probe connected to an AC adapter and the
Probe on, the Probe charges slower than with the
Probe off.
When you send an image to the tester, the battery
uses more power than what the AC adapter supplies
to charge the battery.
The battery status LED shows red while the battery charges. The
LED shows green to indicate the battery is fully-charged. The LED
alternates between red and green to indicate that the battery will
not charge.
Figure 39. Charge the Battery
2
= 4 > 3 > 2
= 1
= 4 »
Red
Green
Red/Green