Fluke Versiv Series - Step 2: Measure the Loss of the Test Reference Cord You will Add

Fluke Versiv Series
377 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Versiv Series Cabling Certification Product Family
Users Manual
180
GPU198.EPS
Figure 68. How to Turn on the Remote’s Optical Source
Step 2: Measure the Loss of the Test Reference
Cord You Will Add
WCaution
If you disconnected the test reference cord from the
output of the tester, you must set the reference
again to make sure your measurements are reliable.
2-1 On the SET REFERENCE screen, when the reference procedure
is completed, tap NEXT.
2-2 Disconnect the test reference cord from the INPUT port on the
tester, then use a test reference cord and adapter to make the
connections to verify the TRCs, as shown on the screen and in
Figure 67.
(continued)
Hold down the button for 3
seconds to turn on the
multimode source.
CFP-QUAD modules: To turn on
the single-mode source, press
the button again.