Versiv Series Cabling Certification Product Family
Users Manual
166
The round icon shows the number of splices entered for the
SPLICES setting on the No. of Connectors/Splices screen.
Bi-directional results show the fibers crossed at the main and
remote ports. The fibers show the connections as they are at
the end of the test.
To see help for the screen, tap .
When more than one button shows at the bottom of the
screen, the tester highlights one in yellow to recommend
which one to tap. See “Buttons to Do Tests and Save Results”
on page 22.
Fiber IDs for Saved Results in Smart Remote Mode
If Auto Save is On and the test passed, the tester saves two
records, one for each fiber. The records have the next two IDs in
the ID list.
If you must change the ID for a fiber before you save results, set
Auto Save to Off before you do the test. Then, on the SAVE
RESULT screen, tap the Input Fiber ID or Output Fiber ID window.
Autotest in Loopback Mode
Use Loopback mode to do tests on spools of cable and segments
of uninstalled cable.
In this mode, the tester measures loss and length at two
wavelengths. If you turn on the Bi-directional function and swap
the fibers halfway through the test, the tester makes
measurements in both directions.
Figure 60 shows the equipment for tests in Loopback Mode.