Versiv Series Cabling Certification Product Family
Users Manual
142
The asset management icon shows when the owner of a
LinkWare Live account has enabled the asset management
service on the tester. “About the Asset Management Service” on
page 352.
This icon shows when the talk function is on. To use the
talk function:
1 Connect the main and remote testers together through a
duplex fiber link.
2 Connect headsets to the headset jacks on the testers.
3 Press the button on one of the headset microphones or
press on the remote, then speak into the
microphone.
Requirements for Reliable Fiber Test Results
To get reliable fiber test results and make sure your tester meets
its accuracy specifications, you must use the correct procedures:
Use proper cleaning procedures to clean all fiber connectors
before every use. See Chapter 4.
Set the reference frequently. See “About the Reference for
Fiber Tests” on page 143.
Use only test reference cords that comply with ISO/IEC
14763-3. Measure the loss of the cords frequently. See “About
Test Reference Cords and Mandrels” on page 146.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com