Versiv Series Cabling Certification Product Family
Users Manual
182
3-5 Tap TEST on the main tester or press on the main or
remote tester.
3-6 If the CHECK FIBER CONNECTIONS screen shows an open
fiber:
• Make sure that all connections are good and no fibers
have damage. Use the VFL to make sure the fiber under
test has continuity.
• If you are connected to a fiber at a patch panel, and you
are not sure you are connected to the correct fiber,
connect the main tester’s INPUT fiber to different
connections until the test continues.
3-7 If Auto Save is on, the tester uses the next ID to save the
results.
If Auto Save is off, the SAVE RESULT screen shows the next
ID available. You can change the ID if necessary.
Note
To put End 1/End 2 results together in the same
record, use LinkWare software to merge the
results.
Autotest Results for Far End Source Mode
Figure 69 shows an example of Autotest results for Far End Source
mode.
Note
The Autotest in Far End Source mode does not
show a PASS/FAIL result, limit, or margin if the
selected test limit uses fiber length to calculate
loss. An example of such a limit is the General
Fiber Optic limit. The tester does not measure
length in Far End Source mode.
www.GlobalTestSupply.com