Versiv Series Cabling Certification Product Family
Users Manual
280
Notes
Since the FaultMap test finds only reflections, do
not use it to look for fusion splices or angled
physical contact (APC) connectors.
FaultMap results do not include a PASS/FAIL status.
The results are only for your documentation of the
link.
FaultMap tests on single-mode fiber usually take
more time than OTDR tests. The test uses very
narrow pulses on single-mode fiber to make the
smallest event dead zones possible, and does
more analysis on the reflections in the link.
How to Do the FaultMap Test
Notes
The FaultMap test does not use the launch
compensation settings.
The FaultMap test uses the wavelength that gives
the best results.
Figure 106 shows the equipment for the FaultMap test.