Versiv Series Cabling Certification Product Family
Users Manual
316
Figure 121. Equipment for Power Meter Measurements
To monitor power
1 Clean and inspect the tester’s input port and the connectors
on the source and test reference cord.
2 Connect the tester to the source, as shown in Figure 122.
3 Turn on the source. On a CertiFiber Pro module, hold down
the button adjacent to the VFL port for 3 seconds.
4 On the home screen, tap TOOLS, then tap Power Meter /
Light Source.
5 The default mode for the power meter is Auto CertiFiber Pro.
If the source is not a CertiFiber Pro tester, tap λ to select the
correct mode.
Figure 123 shows the power meter and its controls.
GPU137.EPS
Main tester with CertiFiber Pro
module installed
One test reference cord
Fiber cleaning supplies
FiberInspector Pro video probe
with USB connector
AC adapter (optional)
A
B
C
E
D
www.GlobalTestSupply.com