Use the OTDR
Settings for OTDR Tests
199
Table 8. Settings for OTDR Tests
Module
Select the OTDR module you will use.
To select a different module, tap the Module panel on the
TEST SETUP screen, then tap a module.
Test Type
When you turn on the tester, the Test Type shows the test
that was last selected.
Auto OTDR: The tester automatically selects settings that
give you the best view of the events on the cabling. This
mode is the easiest to use and is the best choice for most
applications. To see the settings the tester used for an
Auto OTDR test, tap SETTINGS on the trace screen.
Note
Some unusual faults can cause the Auto OTDR
test to show an unsatisfactory trace. If this occurs,
use the Manual OTDR test to get a better trace.
Manual OTDR: This mode lets you select settings to control
the test parameters for the trace. See the Technical
Reference Handbook.