Versiv Series Cabling Certification Product Family
Users Manual
228
1 Clean and inspect the connectors on the launch and tail cords
or patch cords and the link to be tested.
2 Connect the launch cord to the OTDR port and the link to be
tested, as shown in Figure 87. Connect a tail cord to the far
end of the link if necessary.
Or, you can use a patch cord that is 1 m long at minimum to
connect the tester to the link. To see results for the far-end
connector, connect a tail cord or patch cord (>1 m) to the far end
of the link.
3 On the home screen, tap the test setup panel.
4 On the CHANGE TEST screen, tap the button next to the
FaultMap test, then tap USE SELECTED. If a FaultMap test is not
available, tap NEW TEST to add one to the project.
5 Tap TEST or press .