Versiv Series Cabling Certification Product Family
Users Manual
270
: A reflective event, which is usually a non-APC connector.
Measurements for the event are all within the test limits.
: One or more measurements for the event exceeds the
limit. This event could also be a Ghost Source.
Non-reflective loss events:
: A splitter. The number on the splitter shows the split
ratio.
: An APC connector or a splice. Measurements for the event
are all within the test limits.If Macrobend Detection is Off, this
could be a bend. If the event is a bend, and Macrobend
Detection is On, the EventMap shows the bend icon. If the
event has negative loss, it is a Gainer.
: One or more measurements for the event exceeds the
limit.
: A bend with loss that exceeds a macrobend threshold. If
Macrobend Detection is Off, the EventMap shows the blue
circle shown above.
Note
A bend always causes a FAIL result. If you want a
PASS result for a link that has a bend, turn off
Macrobend Detection.