Get Acquainted
AC Adapter and Battery
15
Table 2. Power Button’s LED Indications for Versiv 2 Testers
Green, steady: The tester is on and the AC adapter is not
connected, or the AC adapter is connected and the battery is
fully charged.
Green, flashing: The tester is off, the AC adapter is connected,
and the battery is fully charged.
Red, steady: The tester is on and the battery is charging. The
LED stays red for a few minutes after the battery status icons
show that the battery is fully charged.
Red, flashing: The tester is off and the battery is charging.
Red steady or alternating red/green: The AC adapter is
connected, but the battery is not installed.
Yellow, steady: The tester is on and the AC adapter is
connected, but there is an issue with the battery:
The battery voltage is very low. The AC adapter will trickle-
charge the battery until the voltage increases, then charge
the battery at the normal rate.
The battery will not charge because its temperature is outside
the range of 32 °F to 104 °F (0 °C to 40 °C).
Yellow, flashing: Same as above, but the tester is off.
x5
Yellow, flashes 5 times: This occurs when the tester reboots
after a software update, or if tester reboots because it had an
unrecoverable error.