When you use a test limit that has a reflectance limit, Hidden
events show a fail status if their reflectance exceeds the limit.
: The measurement exceeds the limit.
: The measurement is within the limit.
To see details for the event, tap the window.
To see information for another event, tap another icon on the
map.
Note
Events before the launch cord connector and after
the tail cord connector do not have a pass or fail
status.
Overall Loss: The loss of the cabling. This does not include the
OTDR connection and the loss of the last event. If Launch
Compensation is on, the overall loss includes the launch and tail
connectors, but not the launch and tail fibers.
If you did the test at two wavelengths, the tester shows the
highest loss of the two wavelengths.
N/A shows for the Overall Loss if the tester cannot measure the
loss. This can occur when events are too close together or when
there is a large reflective event near the end of the fiber.
Fiber Length: The length of the fiber. The units show in meters
(m) or feet (ft). If Launch Compensation is on, the length does not
include the length of the launch and tail cords.
PASS/FAIL: The overall result for the fiber.
• PASS: All measurements are within the test limits.
• FAIL: One or more measurements exceed the limit.