371
Appendix B: Modified 1 Jumper
Reference Method
This Appendix shows modified reference and test connections
that give 1 jumper results. Use these connections if you need 1
jumper results, but do not have the correct connector adapters to
connect the CertiFiber Pro modules’ output ports to the link. This
method lets you keep the test reference cords connected to the
module’s output ports when you connect the modules to the link.