5-22
F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
Chap. 5 FUNCTION CODES
Drive control
Code Name Data setting range
Change when
running
Data copying
Default
setting
V/f
PG
V/f
w/o
PG
w/
PG
Torq ue
control
Refer
to
page:
U26 Customizable Logic: (Input 1) See U01. N Y 0 See U01. 5-139
U27 Step 6 (Input 2) See U02. N Y 0 See U02.
U28 (Logic circuit) See U03. N Y 0 Y Y Y Y Y
U29 (Type of timer) See U04. N Y 0 Y Y Y Y Y
U30 (Timer) See U05. N Y 0.00 Y Y Y Y Y
U31 Customizable Logic: (Input 1) See U01. N Y 0 See U01.
U32 Step 7 (Input 2) See U02. N Y 0 See U02.
U33 (Logic circuit) See U03. N Y 0 Y Y Y Y Y
U34 (Type of timer) See U04. N Y 0 Y Y Y Y Y
U35 (Timer) See U05. N Y 0.00 Y Y Y Y Y
U36 Customizable Logic: (Input 1) See U01. N Y 0 See U01.
U37 Step 8 (Input 2) See U02. N Y 0 See U02.
U38 (Logic circuit) See U03. N Y 0 Y Y Y Y Y
U39 (Type of timer) See U04. N Y 0 Y Y Y Y Y
U40 (Timer) See U05. N Y 0.00 Y Y Y Y Y
U41 Customizable Logic: (Input 1) See U01. N Y 0 See U01.
U42 Step 9 (Input 2) See U02. N Y 0 See U02.
U43 (Logic circuit) See U03. N Y 0 Y Y Y Y Y
U44 (Type of timer) See U04. N Y 0 Y Y Y Y Y
U45 (Timer) See U05. N Y 0.00 Y Y Y Y Y
U46 Customizable Logic: (Input 1) See U01. N Y 0 See U01.
U47 Step 10 (Input 2) See U02. N Y 0 See U02.
U48 (Logic circuit) See U03. N Y 0 Y Y Y Y Y
U49 (Type of timer) See U04. N Y 0 Y Y Y Y Y
U50 (Timer) See U05. N Y 0.00 Y Y Y Y Y
U71 Customizable Logic Output Signal 1
(Output selection)
N Y 0 Y Y Y Y Y
U72 Customizable Logic Output Signal 2 N Y 0 Y Y Y Y Y
U73 Customizable Logic Output Signal 3 N Y 0 Y Y Y Y Y
U74 Customizable Logic Output Signal 4 N Y 0 Y Y Y Y Y
U75 Customizable Logic Output Signal 5
0: Disable
1: Step 1 output (SO01)
2: Step 2 output (SO02)
3: Step 3 output (SO03)
4: Step 4 output (SO04)
5: Step 5 output (SO05)
6: Step 6 output (SO06)
7: Step 7 output (SO07)
8: Step 8 output (SO08)
9: Step 1 output (SO09)
10: Step 10 output (SO10)
N Y 0 Y Y Y Y Y
U81 0 (1000): Select multi-frequency (0 to 1 steps) (SS1) Y Y Y Y N
Customizable Logic Output Signal 1
(Function selection)
1 (1001): Select multi-frequency (0 to 3 steps) (SS2)
N Y 100
Y Y Y Y N
U82 Customizable Logic Output Signal 2 2 (1002): Select multi-frequency (0 to 7 steps) (SS4) N Y 100 Y Y Y Y N
U83 Customizable Logic Output Signal 3 3 (1003): Select multi-frequency (0 to 15 steps) (SS8) N Y 100 Y Y Y Y N
U84 Customizable Logic Output Signal 4 4 (1004): Select ACC/DEC time (2 steps) (RT1) N Y 100 Y Y Y Y N
U85 Customizable Logic Output Signal 5 5 (1005): Select ACC/DEC time (4 steps) (RT2) N Y 100 Y Y Y Y N
6 (1006): Enable 3-wire operation (HLD) Y Y Y Y Y
7 (1007): Coast to a stop (BX) Y Y Y Y Y
8 (1008): Reset alarm (RST) Y Y Y Y Y
9 (1009): Enable external alarm trip (THR)
(9 = Active OFF, 1009 = Active ON)
Y Y Y Y Y
10 (1010): Ready for jogging (JOG) Y Y Y Y N
11 (1011): Select frequency command 2/1 (Hz2/Hz1) Y Y Y Y N
12 (1012): Select motor 2 (M2) Y Y Y Y Y
13: Enable DC braking (DCBRK) Y Y Y Y N
14 (1014): Select torque limiter level 2/1 (TL2/TL1) Y Y Y Y Y
15: Switch to commercial power (50 Hz) (SW50) Y Y N N N
16: Switch to commercial power (60 Hz) (SW60) Y Y N N N
17 (1017): UP (Increase output frequency) (UP) Y Y Y Y N
18 (1018): DOWN (Decrease output frequency) (DOWN) Y Y Y Y N
20 (1020): Cancel PID control (Hz/PID) Y Y Y Y N
21 (1021): Switch normal/inverse operation (IVS) Y Y Y Y N
22 (1022): Interlock (IL) Y Y Y Y Y
23 (1023): Cancel torque control (Hz/TRQ)
N N N N Y
24 (1024): Enable communications link via RS-485
or fieldbus (LE)
Y
Y
Y
Y
Y
25 (1025): Universal DI (U-DI) Y Y Y Y Y
26 (1026): Enable auto search for idling motor
speed at starting (STM)
Y
Y
Y
N
Y
30 (1030): Force to stop (STOP)
(30 = Active OFF, 1030 = Active ON)
Y Y Y Y Y