5-141
Function codes for each step
Step No. Input 1 Input 2 Logic circuit
General-purpose
timer
Timer Output
(Note)
Step 1 U01 U02 U03 U04 U05 SO01
Step 2 U06 U07 U08 U09 U10 SO02
Step 3 U11 U12 U13 U14 U15 SO03
Step 4 U16 U17 U18 U19 U20 SO04
Step 5 U21 U22 U23 U24 U25 SO05
Step 6 U26 U27 U28 U29 U30 SO06
Step 7 U31 U32 U33 U34 U35 SO07
Step 8 U36 U37 U38 U39 U40 SO08
Step 9 U41 U42 U43 U44 U45 SO09
Step 10 U46 U47 U48 U49 U50 SO10
(Note) These items shown in this column are output signals, not function codes.
Inputs 1 and 2 (U01, U02, etc.)
The following signals are available as input signals.
Data Selectable Signals
0105 (1105)
General-purpose output signals
(Same as the ones specified by E20):
RUN (Inverter running), FAR (Frequency (speed)
arrival signal),
FDT (Frequency (speed) detected), LU (Undervoltage detected (Inverter
stopped)),
B/D (Torque polarity detected), and other signals.
Note: 27 (Universal DO) is not available.
2001 (3001)
Output of step 1
SO01
2002 (3002)
Output of step 2
SO02
2003 (3003)
Output of step 3
SO03
2004 (3004)
Output of step 4
SO04
2005 (3005)
Output of step 5
SO05
2006 (3006)
Output of step 6
SO06
2007 (3007)
Output of step 7
SO07
2008 (3008)
Output of step 8
SO08
2009 (3009)
Output of step 9
SO09
2010 (3010)
Output of step 10
SO10
4001 (5001)
Terminal [X1] input signal
X1
4002 (5002)
Terminal [X2] input signal
X2
4003 (5003)
Terminal [X3] input signal
X3
4004 (5004)
Terminal [X4] input signal
X4
4005 (5005)
Terminal [X5] input signal
X5
4006 (5006)
Terminal [X6] input signal
X6
4007 (5007)
Terminal [X7] input signal
X7
4010 (5010)
Terminal [FWD] input signal
FWD
4011 (5011)
Terminal [REV] input signal
REV
6000 (7000)
Final run command
FL_RUN
(ON when "frequency command ≠ 0" and a run command is given)
6001 (7001)
Final FWD run command
FL_FWD
(ON when "frequency command ≠ 0" and a run forward command is given)
6002 (7002)
Final REV run command
FL_REV
(ON when "frequency command ≠ 0" and a run reverse command is given)
6003 (7003)
During acceleration
DACC
(ON during acceleration)
6004 (7004)
During deceleration
DDEC
(ON during deceleration)
6005 (7005)
Under anti-regenerative control
REGA
(ON under anti-regenerative control)
6006 (7006)
Within dancer reference position
DR_REF
(ON when the dancer roll position is within the reference range)
6007 (7007)
Alarm factor presence
ALM_ACT
(ON when there is no alarm factor)