6-100 
9  VG Ai (Ai1), VG Ai (Ai2), VG Ai (AIO/AI option, Ai3), VG Ai (AIO/AI option, Ai4) 
(MSB)    (LSB)
15 14 1312 11 1098765432  1  0 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
VG Ai data 
 
  VG Ai data: ±10 V = ±4000 h (±16384d) 
  Note: The AIO option (OPC-VG1-AIO) or AI option (OPC-VG1-AI) is necessary to reference data 
for VG Ai (AIO/AI option, Ai3) / (AIO/AI option, Ai4). 
  To enable this data, you need to assign the corresponding Ai terminal functions to the universal Ai 
(U-AI) using the function codes E49 to E52. If they are not assigned, the value will be 0. 
  To use Ai2, set SW3 on the control board to the V side. (For the switch, refer to Chapter 3, Section 
3.3.3.9 "Setting up the slide switches.") 
 
  Polling function code address and data 
(MSB)    (LSB)
15 14  1 0 
Polling function code 1 address 
Polling function code 1 data 
Polling function code 2 address 
Polling function code 2 data 
 
  "Polling function code 1, 2 address" (16 bits each) store the link number corresponding to the 
function code requested for polling from MICREX-SX. Their data are stored in "Polling function 
code 1, 2 data".