9. Go to the Autopilot Configuration page and navigate to the Roll Tab to configure the servo
direction.
a) The Servo Direction should be set to Normal. The servo arm should move clockwise to
cause a bank left aileron movement and the servo arm should move counterclockwise to
cause a bank right aileron movement.
Figure 30-23 Normal Roll Servo Direction
b) The Servo Direction should be set to Reverse. The servo arm should move clockwise to
cause a bank right aileron movement and the servo arm should move counterclockwise to
cause a bank left aileron movement.