52
Set Alarm
Event
*723_ _ _ _#
Held Open 0
Forced Open 1
Tamper 2
Fire Alarm 3
Access Denied 4
Alarm Time 1-10 sec
For the first blank digit, enter a number from
options 0 to 4. For the second blank digit, type 1
to enable the option and 0 to disable the option.
For the third and fourth blank digits, type the
number of seconds the alarm will sound.
For example, to enable the fire alarm for 3
seconds, press *7233103#
Door/Gate
Function
*343_#
Door Entry Type0
Parking Entry Type1
Door Exit Type2
Parking Exit Type3
Elevator Type4
Door Entry Type: Sets GV-AS110 / 1110 as
entry reader of a door. The Wiegand reader
connected will be set as exit reader.
Parking Entry Type: Sets GV-AS110 / 1110
as entry reader of a parking gate.
Door Exit Type: Sets GV-AS110 / 1110 as
exit reader of a door. The Wiegand reader
connected will be set as entry reader.
Parking Exit Type: Sets GV-AS110 / 1110
as exit reader of a parking gate.
Elevator Type: GV-AS110 / 1110 reader is
installed in the elevator for access control.
For example, to set the GV-AS110 / 1110 as an
exit reader of a door, press *3432#.
Set
Authentication
Mode
*526_#
Schedule Mode0
Fixed Card Mode1
Local Lock Mode2
Local Unlock Mode3
Fixed Card + PIN4
Fixed Card/Common5
Schedule Mode: Follows the authentication
schedule set on GV-ASManager.
Fixed Card Mode: Grants access after the
card is presented. Ignores the authentication
schedule of GV-ASManager.
Local Lock Mode: Remains locked. The
locked state cannot be cleared through GV-
ASManager.
Local Unlock Mode: Remains open. The
held-open state cannot be cleared through
GV-ASManager.
Fixed Card + PIN: Grants access after the
user presents the card and then enters the
card’s PIN code. Ignores the authentication
schedule of GV-ASManager.
Fixed Card/Common: Grants access after
card is presented or after the door’s
password is entered. Ignores the
authentication schedule of GV-ASManager.