GV-AS110 / 1110 Controller
51
2
2.3.2 Programming the GV-AS110 / 1110
The command codes used to program various functions on GV-AS110 / 1110 are listed
below. All command codes will start with an asterisk to clear all previous commands and
end with a number sign # to send the command. After typing the command code, present
the Enroll Card or the Delete Card.
IMPORTANT: Once connecting to GV-AS110 / 1110, GV-ASManager will load its
parameters to GV-AS110 / 1110. That means some of settings you program here may be
overwritten by GV-ASManager later.
Function Command Code
Description
Set Password
779_ _ _ _ _ _ _ _ #
4-8 digits
You can set a password to open the door using
this password. The Authentication Mode must
be set to Fixed Card/Common mode. Refer to
the Set Authentication Mode function below.
For example, to set the door’s password as
12345, press 77912345# on the keypad.
Lock Reset
Time
578_ _ _ #
1-255 seconds
Sets a time that the door/gate will remain open
after which the door will automatically be
locked.
For example, to set the lock reset time to be
120 seconds, press 578120#
Held Open
Time
468_ _ _ _ #
5-9999 seconds
Sets the time that a door/gate can be held open
before an alarm is generated. If the number of
seconds is less than 4 digits, add zeros in front
of the number to make it 4 digits.
For example, to set the held open time to be
180 seconds, enter 4680180#
Set Fire Action
(GV-AS110
only)
732_#
Unchanged0
Unlock Door1
Lock Door2
This function locks or unlocks the door/gate, or
maintains the current status when a fire
emergency occurs.
For example, to unlock door during a fire
emergency, press 7321#
Local Anti-
Passback
527_#
0Disable
1Enable
Local Anti-passback prevents card sharing by
not allowing a card to go through an entry twice
before first exiting.
For example, to enable Local Anti-passback,
press 5271#

Table of Contents

Other manuals for GeoVision GV-AS1010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GeoVision GV-AS1010 and is the answer not in the manual?

GeoVision GV-AS1010 Specifications

General IconGeneral
BrandGeoVision
ModelGV-AS1010
CategoryController
LanguageEnglish

Related product manuals