4.3 Making System Settings
50
Connection method settings (CH 1, 2, 3)
MEASURE
Wiring
Select from pull-
down menu
Confirm
Cancel
1P2W To measure single-phase two-wire power lines
1P3W To measure single-phase three-wire power lines
3P3W2M To measure single-phase three-wire power lines (using
the 2 power meter method)
(Use this when measuring three-phase power with 2-
spot current measurement only.)
3P3W3M
To measure three-phase three-wire power lines (using
the 3 power meter method)
3P4W To measure three-phase four-wire power lines
Connection method settings (CH 4)
MEASURE
Wiring
Select from pull-
down menu
Confirm
Cancel
When set to DC, the voltage of a DC power line can be mea
-
sured.
Regardless of the setting, current can be measured only in AC
power lines.
Even when you set DC, the 0 order harmonic cannot be dis
-
played.
OFF
Set when you are not using channel 4.
AC
Set when measuring the voltage of neutral lines or other
systems.
DC
Set when measuring DC power lines.