Servo Drive Configuration E1 Series Servo Drive Thunder Software Operation Manual
4-76 HIWIN MIKROSYSTEM CORP.
MD12UE01-2012
Figure 4.5.3.3
Table 4.5.3.1
Output condition
Signal type
Satisfied
Not satisfied
Close active
Output digital signal
Do not output digital signal
Open active
Do not output digital signal
Output digital signal
Information
Since the output pins are in pairs (O1+ and O1-, O2+ and O2-…), if users click an output pin,
the other pin will also change its color. For example, if user click O1+, O1- will change its color.
4. Double-click Output number column to assign the digital output signal to any pin or set it as “Not
configure”.