Perform Test Run E1 Series Servo Drive Thunder Software Operation Manual
5-12 HIWIN MIKROSYSTEM CORP.
MD12UE01-2012
Figure 5.3.2
Table 5.3.1
No.
Item
Description
Reference
(1)
Fast homing speed
Set the velocity for finding near home sensor.
Rotary motor (Pt701)
Linear motor (Pt705)
section 8.11.1 in
“E1 Series Servo
Drive User Manual”
(2)
Slow homing speed
Set the velocity for finding home position.
Rotary motor (Pt702)
Linear motor (Pt706)
section 8.11.1 in
“E1 Series Servo
Drive User Manual”
(3)
Timeout
Set the time limit for homing procedure (Pt703).
section 8.11.1 in
“E1 Series Servo
Drive User Manual”
(4)
Home offset
Set home offset (Pt704).
section 8.11.1 in
“E1 Series Servo
Drive User Manual”
(5)
Home method
Select homing method (Pt700).
Table 5.3.3
3. Click Home to execute homing.
(1)
(2)
(3)
(4)
(5)