E1 Series Servo Drive Thunder Software Operation Manual Troubleshooting
HIWIN MIKROSYSTEM CORP. 8-7
MD12UE01-2012
(6)
Refresh
Update the information of History.
(7)
Clear history
Clear all the alarm messages in History.
(8)
Save
Save the current alarm messages as a text file.
Example
Take Figure 8.3.3 as an example:
The cumulative power-on time of servo drive is 167 days, 0 hours, 33 minutes and 26 seconds.
Alarm code (No.): AL810
Alarm message (Error message): Encoder battery undervoltage
Trigger time (Time):
The cumulative power-on time of servo drive is 166 days, 23 hours, 40 minutes and 15 seconds.