E1 Series Servo Drive Thunder Software Operation Manual Thunder Overview
HIWIN MIKROSYSTEM CORP. 1-13
MD12UE01-2012
(85) DBK //external
dynamic brake
output signal
(86) HOMED //servo drive
homing completion
output signal
(87) PAO //encoder
divided pulse output
signal-A phase
(88) PBO //encoder
divided pulse output
signal-B phase
(89) PZO //encoder
divided pulse output
signal-Z phase
(90) INDEX //index signal
(Open PDL)
PDL
Process description language
(Open multi-motion
setting)
Multi-motion setting
Motion
type
(1) Absolute Move
(2) Relative Move
(3) Indexing movement-1
(Reset method: next
motion)
(4) Indexing movement-2
(Reset method: nearest
motion)
(5) JOG
(6) Homing
(7) Customized motion
(Save parameters
as a file)
Save servo drive
parameters file
(*.prm)
Back up parameters as a file to PC.
(Load parameters
from file to drive)
Load servo drive
parameters file
(*.prm)
Reload parameters file back to servo
drive.
(Save to drive)
Send the parameters
to servo drive
Temporarily save parameters file to
memory.
(Reset drive)
Reset drive
Power cycle servo drive.