Page #91 background image
E1 Series Servo Drive Thunder Software Operation Manual Servo Drive Configuration
HIWIN MIKROSYSTEM CORP. 4-27
MD12UE01-2012
2. Set the related parameters of command input.
Figure 4.3.6.2.2
Table 4.3.6.2.2
No.
Item
Description
(1)
Pulse format
parameters setting
Select pulse type (Pt200.0) and pulse filter (Pt200.3), and set pulse
input ratio (Pt218). Refer to section 8.4 in “E1 Series Servo Drive
User Manual” for further descriptions of pulse command input.
(2)
Diagram
It shows the CN6 pin diagram of pulse command input signal and the
pulse signal diagram.
3. Click electronic gear ratio setting icon to open “Electronic gear ratio setting” window for
electronic gear ratio setting.
(2)
(1)

Table of Contents

Other manuals for Hiwin E1 Series

Questions and Answers:

Question and Answer IconNeed help?