Ext Det Cal
Function Group
Menu Map
Description
Programming Codes
See Also
ENTRY
NONE
This
softkey
lets you turn off (blank) the active entry area and
disable the ARROW keys, rotary knob, and entry keys. When
any function key (hard or soft) is pressed, the active entry area is
reactivated. The yellow LED, ENTRY ON, next to (ENTRY ON/OFF)
indicates whether the entry area is active (LED on=active).
SCPI: No specific code activates (ENTRY ON/OFF)
Analyzer:EF=off
Arrow Keys
“Entry Area” in Chapter 1
Ext Det Cal
Function Group
USER CAL
Menu Map
9
Description
This
softkey
enables the swept CW generator to act as a controller to
an HP 437B power meter. This
softkey
causes an immediate execute
on the interface bus and generates an HP-IB error if no power meter
is present on the interface bus or if the swept CW generator is unable
to address the power meter. Use external detector calibration to
characterize and compensate for an external negative diode detector
used in an external leveling configuration.
Programming Codes
SCPI:
CALibration:PMETer:DETector:INITiate?
DIODe
CALibration:PMETer:DETector:NEXT? <num>[lvl suffix]
Analyzer:NONE
See Also
“Optimizing Swept CW Generator Performance” in Chapter 1
Operating and Programming Reference E-5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 8360 L Series and is the answer not in the manual?

HP 8360 L Series Specifications

General IconGeneral
BrandHP
Model8360 L Series
CategoryInverter
LanguageEnglish

Related product manuals