EasyManua.ls Logo

HP 8360 L Series - Step Points; Stepsize

HP 8360 L Series
429 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step Points
Function Group
Menu Map
Description
Programming Codes
See Also
FREQUENCY
2
This
softkey
lets you define the number of step points in a stepped
frequency sweep. The number of points in a stepped sweep can
range from 2 to 801. Step Size and Step Points are dependent
variables. If you know how many steps are desired in a given sweep,
use the
softkey
Step Points to set the desired value The step size
will be calculated automatically.
SCPI: SWEep[:FREQuency]:POINts
<num>]MAXimum]MINimum
Analyzer: NONE
Step Size, Step Swp Menu, Sweep Mode Step
“Using Step Sweep” in Chapter 1
Step Size
Function Group
Menu Map
Description
Programming Codes
See Also
FREQUENCY
2
This
softkey
lets you specify the step size in a stepped frequency
sweep. The range of increment size is dependent on frequency
span and the number of step points desired, as given by the
formula: STEP SIZE = SPAN
+
STEP POINTS. Step Size and
Step Points are dependent variables, as shown by the formula. If
a particular step size is desired, use the Step Size softkey to set
the desired increment. The number of step points is then calculated
automatically.
SCPI: SWEep[:FREQuency]:STEP <num>[freq suffix] or
MAXimumlMINimum
Analyzer: NONE
Step Points, Step
Sup
Menu, Sweep Mode Step
“Using Step Sweep” in Chapter 1
S-60 Operating and Programming Reference

Table of Contents

Related product manuals