HP 8360 L Series - Start Sweep Trigger Auto; Start Sweep Trigger Bus

HP 8360 L Series
429 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Start Sweep
Trigger Auto
Function Group
Menu Map
Description
Programming Codes
See Also
Start
Sweep
Trigger Bus
SWEEP
7
When this
softkey
is selected, the swept CW generator automatically
triggers a sweep. This is the fastest way to accomplish the
sweep-retrace cycle. An asterisk next to the key label indicates that
this feature is active.
SCPI: TRIGger:SOURce
IMMediate
Analyzer:
Tl
(CONT),
I-)),
Sweep Menu
Start Sweep
Trigger
3us
Function Group
Menu Map
Description
Programming Codes
See Also
SWEEP
7
When this
softkey
is selected, the swept CW generator waits for an
HP-IB trigger to trigger a sweep. An asterisk next to the key label
indicates that this feature is active.
SCPI: TRIGger:SOURce BUS
Analyzer: TS
(CONT),
Cm)),
Sweep Menu
Operating and Programming Reference S-55

Table of Contents