Saving
and
The save/recall registers store and access a previously set instrument
Recalling
an
state.
Instrument
State
For example, set the swept CW generator to sweep from 3 to 15
GHz at a -10 dB power level, with markers 1 and 2 set at 4.5 and
11.2 GHz.
Press (START)
(?J
LGHz).
Press
LSTOP)
(iJ
@
(GHz).
Press (POWER LEVEL)
(-)
(iJ
(TJ
IdBo).
Press
(MARKER).
Select Marker Ml
@
0
@
IGHz).
Select Marker M2
(iJ
0
0
@
LGHz).
To save this instrument state in register 1, press
(SAVE]
(iJ. To verify
that the swept CW generator has saved this state:
Press
[PRESET).
Press
IRECALL]
0.
Press
(MARKER).
The active entry area displays:
-->
RECALL REGISTER: 1 RECALLED
Notice the sweep end points, power level, and the asterisks next to
the marker 1 and 2 key labels.
You can save instrument states in registers 1 through 8. Register
0 saves the last instrument state before power is turned off. When
power is turned on, register 0 is automatically recalled.
1-16 Getting Started Basic