General
Environmental
Warmup Time
Power Requirements
48 to 66 Hz; 115 volts (-l-10/--25%) or 230 volts (+10/-15%/o);
400 VA maximum (30 VA in standby)
Weight
&
Dimensions
Net Weight: 27 kg (60 lb)
Shipping Weight: 36 kg (80 lb)
Dimensions: 178 H x 425 W x 648 mm D (7.0 x 16.75 x 25.5 inches)
Adapters Supplied
HP
83623L,
HP 83630L
Type-N (female)
-
3.5 mm (female)
3.5 mm (female)
-
3.5 mm (female)
HP
8364OL,
HP 83650L
2.4 mm (female)
-
2.92 (female)
2.4 mm (female)
-
2.4 mm (female)
Operating Temperature Range: 0 to 55
“C
Altitude: Up to 4572 meters
Humidity: 5 to 80% relative at
+25
to 40
“C
Enclosure Protection:
IP20,
according to IEC 529
This product is designed for use in INSTALLATION CATEGORY II
and POLLUTION DEGREE 2, per IEC 1010 and 664 respectively.
EMC: Within limits of CISPR Pub. 11/1990 Group 1, Class A, and
Mil-Std-461C Part 7 RE02
Operation: Requires 30 minute warm-up from cold start at 0
to 55
“C.
Internal temperature equilibrium reached over 2 hour
warm-up at stable ambient temperature.
F’requency
Reference: Reference time base is kept at operating
temperature with the instrument connected to AC power.
Instruments disconnected from AC power for more than 24 hours
require 30 days to achieve time base aging specification. Instruments
disconnected from AC power for less than 24 hours require 24 hours
to achieve time base aging specification.
Part number 1250-1745
Part number 5061-5311
Part number 1250-2187
Part number 1250-2188
2c-10
Specifications