EasyManuals Logo

HP P2000 G3 Cli Reference Guide

HP P2000 G3
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
134 Alphabetical list of commands
compact-flash-failure enabled|disabled|on|off
Optional. Sets whether the cache policy will change from write-back to write-through when
CompactFlash memory is not detected during POST (Power-On Self-Test), fails during POST, or fails
during controller operation.
disabled or off: The CompactFlash failure trigger is disabled.
enabled or on: The CompactFlash failure trigger is enabled. This is the default.
controller-failure enabled|disabled|on|off
Optional. Sets whether the cache policy will change from write-back to write-through when a
controller fails.
disabled or off: The controller failure trigger is disabled. This is the default.
enabled or on: The controller failure trigger is enabled.
dynamic-spares enabled|disabled|on|off
Optional. Sets whether the storage system will automatically designate an available compatible disk
as a spare to replace a failed disk in a vdisk. A compatible disk has enough capacity to replace the
failed disk and is the same type (SAS or SATA).
disabled or off: The dynamic spares feature is disabled. This is the default.
enabled or on: The dynamic spares feature is enabled.
emp-poll-rate rate
Optional. Sets the interval at which the storage system will poll each enclosure's Enclosure
Management Processor (EMP) for status changes, from 5–3600 seconds. The default is 5 seconds.
fan-failure enabled|disabled|on|off
Optional. Sets whether the cache policy will change from write-back to write-through when a fan
fails.
disabled or off: The fan failure trigger is disabled. This is the default.
enabled or on: The fan failure trigger is enabled.
host-cache-control enabled|disabled|on|off
Optional. Sets whether hosts are allowed to use the SCSI MODE SELECT command to change the
storage system's write-back cache setting.
disabled or off: Host control of caching is disabled. This is the default.
enabled or on: Host control of caching is enabled.
independent-cache enabled|disabled|on|off
Not supported. Disabled by default.
managed-logs enabled|disabled|on|off
Optional. Enables or disables the managed logs feature, which allows log files to be transferred
from the storage system to a log collection system to avoid losing diagnostic data.
disabled or off: The managed logs feature is disabled. This is the default.
enabled or on: The managed logs feature is enabled.
missing-lun-response notready|illegal
Optional. Sets whether host drivers may probe for LUNs until the host drivers reach the LUN to which
they have access.
notready: Sends a reply that there is a LUN where a gap has been created but that it’s “not
ready.” Sense data returned is sensekey = 2, code = 4, qualifier = 3. This option is the default.
illegal: Sends a reply that there is a LUN but that the request is “illegal.” Sense data returned
is sensekey = 5, code = 25h, qualifier = 0. If the system is used in a VMware environment, use
this option.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures