HP P2000 G3 MSA System CLI Reference Guide 135
partner-firmware-upgrade enabled|disabled|on|off
Optional. Sets whether component firmware versions are monitored and will be automatically
updated on the partner controller.
disabled or off: Partner firmware upgrade is disabled.
enabled or on: Partner firmware upgrade is enabled. This is the default.
partner-notify enabled|disabled|on|off
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner continue using its current caching mode for better performance. The
default is disabled.
disabled or off: Notification is disabled. This is the default.
enabled or on: Notification is enabled.
power-supply-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a power
supply fails.
disabled or off: The power-supply failure trigger is disabled. This is the default.
enabled or on: The power-supply failure trigger is enabled.
smart enabled|disabled|on|off|detect-only
Optional. Enables or disables SMART (Self-Monitoring Analysis and Reporting Technology)
monitoring for all disks in the storage system.
disabled or off: Disables SMART for all disks in the system and for all disks added to the
system.
enabled or on: Enables SMART for all disks in the system and for all disks added to the system.
This is the default.
detect-only: Detects but does not change the SMART setting of each disk in the system, and
for each new disk added to the system.
super-cap-failure enabled|disabled|on|off
Optional. Sets whether the cache policy will change from write-back to write-through when the
super-capacitor that provides backup power for cache is not fully charged or fails.
disabled or off: The super-capacitor failure trigger is disabled.
enabled or on: The super-capacitor failure trigger is enabled. This is the default.
sync-cache-mode immediate|flush
Optional. Sets how the SCSI SYNCHRONIZE CACHE command is handled.
immediate: Good status is returned immediately and cache content is unchanged. This option
is the default.
flush: Good status is returned only after all write-back data for the specified volume is flushed
to disk.
temperature-exceeded enabled|disabled|on|off
Optional. Sets whether the system will shut down a controller when its temperature exceeds the
critical operating range.
disabled or off: The over-temperature trigger is disabled. This is the default.
enabled or on: The over-temperature trigger is enabled.

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures