EasyManuals Logo

HP P2000 G3 Cli Reference Guide

HP P2000 G3
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #347 background imageLoading...
Page #347 background image
HP P2000 G3 MSA System CLI Reference Guide 347
dynamic-spares string Shows whether the storage system will automatically use a compatible disk as a
spare to replace a failed disk in a vdisk if no compatible spare is available.
Disabled: The dynamic spares feature is disabled. This is the default.
Enabled: The dynamic spares feature is enabled.
emp-poll-rate uint32 Shows the interval in seconds at which the storage system will poll each
enclosure's Enclosure Management Processor (EMP) for status changes, from
5–3600 seconds. The default is 5 seconds.
host-cache-
control
string Shows whether hosts are allowed to use the SCSI MODE SELECT command to
change the storage system's write-back cache setting.
Disabled: Host control of caching is disabled. This is the default.
Enabled: Host control of caching is enabled.
host-cache-
control-numeric
string Numeric equivalents for host-cache-control values.
0: Disabled
1: Enabled
sync-cache-mode string Shows how the SCSI SYNCHRONIZE CACHE command is handled.
Immediate: Good status is returned immediately and cache content is
unchanged. This is the default.
Flush To Disk: Good status is returned only after all write-back data for
the specified volume is flushed to disk.
sync-cache-
mode-numeric
string Numeric equivalents for sync-cache-mode values.
0: Immediate
1: Flush to Disk
independent-
cache
string Shows the cache redundancy mode for a dual-controller storage system.
Not supported. Disabled by default.
independent-
cache-numeric
string Numeric equivalents for independent-cache values.
0: Disabled
1: Enabled
missing-lun-
response
string Shows whether host drivers may probe for LUNs until the host drivers reach the
LUN to which they have access.
Not Ready: Sends a reply that there is a LUN where a gap has been
created but that it’s “not ready.” Sense data returned is sensekey = 2, code =
4, qualifier = 3. This is the default.
Illegal Request: Sends a reply that there is a LUN but that the request
is “illegal.” Sense data returned is sensekey = 5, code = 25h, qualifier = 0.
missing-lun-
response-
numeric
string Numeric equivalents for missing-lun-response values.
0: Not Ready
1: Illegal Request
controller-
failure
string Shows whether the cache policy will change from write-back to write-through
when a controller fails.
Disabled: The controller failure trigger is disabled. This is the default.
Enabled: The controller failure trigger is enabled.
controller-
failure-numeric
string Numeric equivalents for controller-failure values.
0: Disabled
16: Enabled
Table 9 advanced-settings-table properties (continued)
Name Type Description

Table of Contents

Other manuals for HP P2000 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P2000 G3 and is the answer not in the manual?

HP P2000 G3 Specifications

General IconGeneral
ModelP2000 G3
CategoryStorage
Drive SupportSAS, SATA
Host InterfaceiSCSI, Fibre Channel, SAS
Form Factor2U
RAID Levels0, 1, 5, 6, 10
Cache2 GB
Drive Bays12 (SFF), 24 (SFF), 12 (LFF)
Cache Memory2GB per controller
Operating Temperature10°C to 35°C
Power SupplyRedundant
Expansion OptionsDisk Enclosures