EasyManua.ls Logo

HP P2000 G3

HP P2000 G3
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
348 XML API basetype properties
super-cap-
failure
string Shows whether the cache policy will change from write-back to write-through
when the super-capacitor that provides backup power for cache is not fully
charged or fails.
Disabled: The super-capacitor failure trigger is disabled.
Enabled: The super-capacitor failure trigger is enabled. This is the default.
super-cap-
failure-numeric
string Numeric equivalents for super-cap-failure values.
0: Disabled
4: Enabled
compact-flash-
failure
string Shows whether the cache policy will change from write-back to write-through
when CompactFlash memory is not detected during POST (Power-On Self-Test),
fails during POST, or fails during controller operation.
Disabled: The CompactFlash failure trigger is disabled.
Enabled: The CompactFlash failure trigger is enabled. This is the default.
compact-flash-
failure-numeric
string Numeric equivalents for compact-flash-failure values.
0: Disabled
512: Enabled
power-supply-
failure
string Shows whether the cache policy will change from write-back to write-through
when a power supply fails.
Disabled: The power-supply failure trigger is disabled. This is the default.
Enabled: The power-supply failure trigger is enabled.
power-supply-
failure-numeric
string Numeric equivalents for power-supply-failure values.
0: Disabled
64: Enabled
fan-failure string Shows whether the cache policy will change from write-back to write-through
when a fan fails.
Disabled: The fan failure trigger is disabled. This is the default.
Enabled: The fan failure trigger is enabled.
fan-failure-
numeric
string Numeric equivalents for fan-failure values.
0: Disabled
128: Enabled
temperature-
exceeded
string Shows whether the system will shut down a controller when its temperature
exceeds the critical operating range.
Disabled: The over-temperature trigger is disabled. This is the default.
Enabled: The over-temperature trigger is enabled.
temperature-
exceeded-
numeric
string Numeric equivalents for
temperature-exceeded values.
0: Disabled
8: Enabled
partner-notify string Shows whether the partner controller will be notified when a trigger condition
occurs.
Disabled: Notification is disabled; the partner controller will continue
using its current caching mode. This is the default.
Enabled: Notification is enabled; the partner controller will change to
write-through mode for better data protection.
partner-notify-
numeric
string Numeric equivalents for partner-notify values.
0: Disabled
2: Enabled
Table 9 advanced-settings-table properties (continued)
Name Type Description

Table of Contents

Other manuals for HP P2000 G3

Related product manuals