HP P2000 G3 MSA System CLI Reference Guide 375
iob string Shows whether resource-count debug messages for an I/O interface driver are
enabled for inclusion in the Storage Controller debug log.
Off: Disabled. This is the default.
On: Enabled.
iob-numeric string Numeric equivalents for iob values.
0: Off
1: On
ioc string Shows whether upper-layer, verbose debug messages for an I/O interface driver
are enabled for inclusion in the Storage Controller debug log.
Off: Disabled. This is the default.
On: Enabled.
ioc-numeric string Numeric equivalents for ioc values.
0: Off
1: On
iod string Shows whether lower-layer, verbose debug messages for an I/O interface driver
are enabled for inclusion in the Storage Controller debug log.
Off: Disabled. This is the default.
On: Enabled.
iod-numeric string Numeric equivalents for iod values.
0: Off
1: On
misc string Shows whether internal debug messages are enabled for inclusion in the
Storage Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
misc-numeric string Numeric equivalents for misc values.
0: Off
1: On
rcm string Shows whether removable-component manager debug messages are enabled
for inclusion in the Storage Controller debug log.
Off: Disabled. This is the default.
On: Enabled.
rcm-numeric string Numeric equivalents for rcm values.
0: Off
1: On
raid string Shows whether RAID debug messages are enabled for inclusion in the Storage
Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
raid-numeric string Numeric equivalents for raid
values.
0: Off
1: On
Table 21 debug-log-parameters properties (continued)