HP P2000 G3 MSA System CLI Reference Guide 377
res2 string Shows whether internal debug messages are enabled for inclusion in the
Storage Controller debug log.
Off: Disabled. This is the default.
On: Enabled.
res2-numeric string Numeric equivalents for res2 values.
0: Off
1: On
capi2 string Shows whether Internal Configuration API tracing messages are enabled for
inclusion in the Storage Controller debug log.
Off: Disabled. This is the default.
On: Enabled.
capi2-numeric string Numeric equivalents for capi2 values.
0: Off
1: On
dms string Shows whether Snapshot feature debug messages are enabled for inclusion in
the Storage Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
dms-numeric string Numeric equivalents for dms values.
0: Off
1: On
fruid string Shows whether FRU ID debug messages are enabled for inclusion in the Storage
Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
fruid-numeric string Numeric equivalents for fruid values.
0: Off
1: On
resmgr string Shows whether Reservation Manager debug messages are enabled for inclusion
in the Storage Controller debug log.
Off: Disabled. This is the default.
On: Enabled.
resmgr-numeric string Numeric equivalents for resmgr values.
0: Off
1: On
init string Not used.
init-numeric string Not used.
ps string Not used.
ps-numeric string Not used.
hb string Not used.
hb-numeric string Not used.
Table 21 debug-log-parameters properties (continued)