EasyManua.ls Logo

HPE FlexNetwork MSR Series - Page 95

HPE FlexNetwork MSR Series
213 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
89
The 8-port fractional T1 interface module allows only one bundle. The time slots can only be
bundled into one n × 64 Kbps/56 Kbps channel, where the value range of n is 1 to 31. The
module does not support the PRI mode.
HMIM-8E1T1(-F) jumper settings
You can set an interface to a 75-ohm E1 interface, 100-ohm T1 interface, or 120-ohm E1
interface at the CLI or by using the jumper connection method. By default, an interface is a
75-ohm E1 interface.
For a 75-ohm E1 interface, the jumper is connected to pins 1 and 2, pins 7 and 8, and pins
11 and 12.
For a 100-ohm T1 or 120-ohm E1 interface, the jumper is connected to pins 1 to 3, pins 5 to
7, pins 9 and 10, and pins 11 to 13.
Figure 105 Jumper settings
NOTE:
An interface corresponds to a jumper connector. Pin settings for the jumper connectors are
the
same.
Each interface comes with four jumper caps.
All interfaces must operate in the same mode simultaneously.
J50
J
51 J52
J53 J
54 J55 J
57
J56
J4 J5 J6 J
7 J8 J
9 J10 J11
13 11 9 7 5 3 1
14 12 10 8 6 4 2
T
1 100 ohm
E
1 120 ohm
13 11 9 7 5 3 1
14 12 10 8 6 4 2
E1 75 ohm