90
Interface specifications
Table 140 Interface specifications
Item
Specification
Connector type RJ-45
Number of connectors 8
Interface standard
G.703/G.704
T1 102
AT&T TR 54016
AT&T TR 62411
ANSI T1.403
Interface rate
1.544 Mbps
2.048 Mbps
Supported cable
E1 75-ohm unbalanced twisted pair cable
E1 120-ohm balanced twisted pair cable, 2 m (6.56 ft), 15 m (49.21 ft), or 30 m
(98.43 ft)
T1 cable (100-ohm shielding network cable)
Coaxial connector, network connector, 75-to-120-ohm adapter (with BNC
connector)
Operating mode
E1/T1/CE1T1/ISDN PRI (only supported by the HMIM-8E1T1)
FE1T1 (only supported by the HMIM-8E1T1-F)
Supported services
Backup
Terminal access service
ISDN PRI (only supported by the HMIM-8E1T1)
Interface LEDs
Figure 106 HMIM-8E1T1 panel
Figure 107 HMIM-8E1T1-F panel
Table 141 LED description
LED
Description
LINK/ACT
On means the carrier signal has been received.
Off means no carrier signal has been received.
Flashing means data is being transmitted or/and received.
LP/AL
On means the interface is in a loopback.
Off means no loopback or alarm is present.
Flashing means an AIS, LFA signal, or RAI signal is present.