l During parts replacement, keep new server components in ESD bags before installation,
and place removed server components on conductive mats for temporary storage.
l Do not touch welding points, pins, or exposed circuits.
12.2 ESD Wrist Strap
A cabinet or chassis is properly grounded.
Step 1 Put on the ESD wrist strap. See Figure 12-2.
Figure 12-2 Wearing an ESD wrist strap
Step 2 Tighten the ESD wrist strap to ensure that it is in good contact with your bare skin.
Step 3 Insert the ground terminal of the ESD wrist strap into the ESD jack in a cabinet or chassis.
----End
TaiShan 2280 V2 Server
User Guide
12 Preventing Electrostatic Discharge
Issue 01 (2019-07-01) Copyright © Huawei Technologies Co., Ltd. 139