Product Name: TaiShan 2280 V2
iME Version: 0.66
BIOS Version: U75)0.90
-------------- Mother Board INFO ---------------
Mainboard BoardID: 0x00b9
Mainboard PCB: .A
--------------- Riser Card INFO ----------------
Riser1 BoardName: BC11PRUCRiser1
BoardID: 0x0090
Riser1 PCB: .A
Riser2 BoardName: BC82PRNE
Riser2 BoardID: 0x0032
Riser2 PCB: .A
------------------- HDD Backplane INFO -------------------
Disk BP1 BoardName: BC11THBQ
Disk BP1 BoardID: 0x0073
Disk BP1 PCB: .A
Disk BP1 CPLD Version:(U3)1.10
-------------------- IO Board INFO -------------------
IOBoard5 ProductName: BC82IOBA
IOBoard5 BoardID: 0x0069
IOBoard5 PCB: .A
IOBoard5 CPLD Version: (U12)0.01
n CPLD Version: complex programmable logical device (CPLD) version of the
TaiShan 2280 V2
n BIOS Version: BIOS version of the TaiShan 2280 V2
n Active iBMC Version: active iBMC version of the TaiShan 2280 V2
n Backup iBMC Version: backup iBMC version of the TaiShan 2280 V2
e. Query the health status of the TaiShan 2280 V2.
iBMC:/->ipmcget -d health
System in health state
n If "System in health state" is displayed, no further action is required.
n If alarm information is displayed, go to the next step.
f. Query any generated alarms.
iBMC / # ipmcget -d healthevents
Event Num | Event Time | Alarm Level | Event Code | Event
Description
1 | 2019-02-10 00:52:23 | Minor | 0x12000021 | get
description failed.
2 | 2019-02-10 01:37:42 | Minor | 0x12000013 | Failed
to obtain data of the air inlet temperature.
3 | 2019-02-10 00:52:23 | Minor | 0x12000019 | Right
mounting ear is not present.
4 | 2019-02-10 00:52:19 | Major | 0x28000001 | The
SAS or PCIe cable to front disk backplane is incorrectly connected.
g. Clear alarms. For details, see the TaiShan Rack Server iBMC Alarm Handling.
----End
4.6.6 Changing Initial Passwords
Change the following initial user passwords:
l Initial password of the default iBMC user
l Initial password for the iBMC U-Boot
TaiShan 2280 V2 Server
User Guide
4 Setup
Issue 01 (2019-07-01) Copyright © Huawei Technologies Co., Ltd. 75

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei TaiShan 2280 V2 and is the answer not in the manual?

Huawei TaiShan 2280 V2 Specifications

General IconGeneral
BrandHuawei
ModelTaiShan 2280 V2
CategoryServer
LanguageEnglish

Related product manuals