3.1 Powering On the Server
Power on the server using one of the following methods based on the actual situation:
l If the PSUs are properly installed but are not connected to an external power supply:
Connect the external power supply to the PSUs. Then the server will power on with the
PSUs.
NOTE
The default value of System State Upon Power Supply is Power on, which indicates that the
server automatically powers on after power is supplied to the PSUs. To change the value of
System State Upon Power Supply, log in to the iBMC WebUI and choose Power > Power
Control.