2.9.3 NVMe SSD Indicators
Figure 2-25 shows the NVMe SSD indicators.
Figure 2-25 NVMe SSD indicators
Table 2-11 NVMe SSD indicators
Green Indicator
Yellow
Indicator
State Description
Off Off The NVMe SSD cannot be detected.
Steady green Off The NVMe SSD is detected and working
properly.
Blinking green (2
Hz)
Off Data is being read from or written to the NVMe
SSD.
Steady green Blinking yellow
(2 Hz)
The NVMe SSD is being located or hot-swapped.
Steady green Blinking yellow
(0.5 Hz)
The NVMe SSD completes the hot removal
process and is removable.
Steady green or
off
Steady yellow The NVMe SSD is faulty.
2.10 Riser Cards and PCIe Slots
Figure 2-26, Figure 2-27, Figure 2-28, Figure 2-29, and Figure 2-30 show riser cards
supported by I/O modules 1 and 2 in a TaiShan 2280 V2.
l The riser card shown in Figure 2-26 can be installed in I/O module 1 or 2. It provides
PCIe slots 1 to 3 when installed in I/O module 1 and PCIe slots 4 to 6 when installed in
I/O module 2.
TaiShan 2280 V2 Server
User Guide
2 Components