l ECC
l SEC/DED
l SDDC
l Patrol scrubbing
5.8.6 DIMM Installation Rules
l General DIMM Installation Rules
Install DIMMs only when the corresponding CPU is installed.
Do not install LRDIMMs and RDIMMs on the same server.
5.8.2 Memory Subsystem Architecture provides the DIMM installation sequence.
When installing DIMMs in a memory channel, install DIMMs with more ranks and
then DIMMs with fewer ranks (starting from the slot farthest from the CPU in the
channel). For example, install quad-rank DIMMs, then dual-rank DIMMs, and then
sing-rank DIMMs.
Install DIMM fillers in vacant DIMM slots.
l DIMM Installation Rules for Specific Modes
Installation Rules for the Memory Sparing Mode
n Follow the general DIMM installation rules.
n The spare configuration of each channel must be valid.
n Different channels can have different spare configurations.
n Each channel with DIMMs installed must have a spare rank.
Installation Rules for the Memory Mirroring Mode
n Follow the general DIMM installation rules.
n Install DIMMs in either channels 1 and 2, or channels 3 and 4. The installed
DIMMs must be of the same size and organization.
n For a multi-CPU configuration, each CPU must have a valid memory
mirroring configuration.
Installation Rules for the Memory Patrol Mode
See the general DIMM installation rule.
5.8.7 Installing a DIMM
Step 1 Wear an ESD wrist strap. For details, see 12 Preventing Electrostatic Discharge.
Step 2 Power off the server. For details, see 3.2 Powering Off the Server.
Step 3 Remove the power cables. For details, see 3.4 Removing Cables from a PSU.
Step 4 Remove the server. For details, see 3.3 Removing the Server and Guide Rails.
Step 5 Remove the chassis cover. For details, see 3.6 Removing the Chassis Cover.
Step 6 Remove the air duct. For details, see 3.10 Removing the Air Duct.
Step 7 Take a spare DIMM out of the DIMM box.
Step 8 Open the two fixing clips of the DIMM slot. See Figure 5-18.
TaiShan 2280 V2 Server
User Guide
5 Optional Part Installation
Issue 01 (2019-07-01) Copyright © Huawei Technologies Co., Ltd. 101